The MAC 1600 Battery Pack contains lithium-ion batteries. Lithium Ion (Li-ion) batteries last longer than conventional batteries and do not require replacement as often. The lithium ion technology used is significantly less hazardous to the environment. Are trademarks owned by GE Medical Systems Information Technologies, a division of General Electric Company going to market as GE Healthcare. All other marks are not owned by GE and are instead owned by their respective owners. NOTE This manual applies to the MAC™ 800 Resting ECG Analysis System, software version 1.
Everything you need to stay productive.
GE’s electrocardiographs are not only known for
standing the test of time, but are designed with
features to maximize department uptime so you
can spend more time focusing on your patients.
Supplies & Accessories
• The MAC 1600
comes with
a range of
tested, high-
performance
accessories that
are specifically
designed for
optimum connection
with your patients.
• Multi-link patient cable with replaceable leadwires,
available with both AHA and IEC labeling
• Value cable with dedicated leadwires
• Disposable electrodes
• Re-usable electrodes
• Paper options and sizes
• KISS System – 12-lead suction and application system

(reusable electrodes), integrated pump (option).
Service
• Uncompromising service with GE’s team
of experienced technicians
Comprehensive training
• Easy-to-learn – The computer-based training DVD
includes a complete suite of MAC 1600 clinical
education tools that make it easy to learn more
about the MAC 1600.
Acquisition & analysis
• Analog acquisition module
• Marquette 12SL measurements & interpretation
(option)

• Marquette 12SL Hookup Advisor
• 4.88 mV resolution
Display
• Type: 7' TFT LCD module, widescreen
• Display resolution: 800 x 480 pixels
• WVGA resolution – same as 800 x 480
• Color
• VGA port for external CRT monitor
Writer
• Resolution: Vertically 8 dots/mm,
horizontally 40 dots/mm @25 mm/sec
• Paper type: thermal A4 & US letter, Z-fold
• Writer speed: 5, 12.5, 25, 50 mm/sec
Processing
• 12 lead simultaneous analysis
• 500 or 1000 samples/sec
Memory
• Internal/external 100 ECGs (option)
Connectivity, communication,
input devices
Mac 1600 Service Manual
• LAN transmission to MUSE or CardioSoft (options),
Ge Mac 1600 Technical Manual Instructions
GE’s ECG management systems
• Internal modem (option)
• Secure digital card
• GE supported USB barcode with advanced
symbologies: Code 39 (extended), PDF-417,
Code 128, Data Matrix, Interleaved 2 of 5 (option).
Keyboard
Ge Mac 1600 Service Manual
• Type: Elastomer - with soft function keys,
alphanumeric keys, writer controls and
Trim Pad cursor controls
Smart.
The MAC 1600’s resting ECG function can be easily configured
to meet the needs of nearly every environment. With quick
assessment of the ECG signal quality, the availability of
GE’s Marquette 12SL ECG analysis program, and an easy
connection to your ECG cardiology management system,
the new MAC 1600 couldn’t be smarter.
•
Diagnostic confidence – Recognized across the globe
as one of the most validated programs in the industry,
the optional GE Marquette 12SL ECG analysis program
provides true, computer-interpreted analysis of adult
and pediatric populations.
•
Signal quality – The Marquette 12SL Hookup Advisor
*
ensures ECG signal quality from the start. This exclusive
GE algorithm goes beyond simple electrical checks
to advise clinicians of poor waveform quality during
the recording of ECGs.
•
Easy configuration – The MAC 1600 automatically
captures 10-second ECGs with one-touch operation.
Additionally, you can select the rhythm ECG mode
to continuously review all 12 leads, or the arrhythmia
mode for an extended review of arrhythmias or events.
•
Comprehensive – The MAC 1600 offers more than just
acquisition. Its online editing and re-analysis of ECG
waveform capabilities enhance the accuracy of
patients’ records.